




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
HowtoEvaluateRiskinthe
MedicalLaboratoryJamesH.Nichols,PhD,DABCC,FACBProfessorofPathology,MicrobiologyandImmunologyMedicalDirectorofClinicalChemistryandPoint-of-CareTestingVanderbiltUniversitySchoolofMedicineMedicalDirector,ClinicalChemistryNashville,Tennessee,USAjames.h.nichols@
1Objectives1.Discussthesourcesoferrorinthemedicallab2.ReviewQCasameansofcontrollinganalyticalerror3.Identifyriskmanagementasatotalqualityassuranceofthetestingprocess4.Describeregulatorychangesadoptingriskmanagementinthelaboratory
2MedicalErrorAnadverseeventornearmissthatispreventablewiththecurrentstateofmedicalknowledge.(theQualityInteragencyCoordinationTaskForce)
MedicalErrorsInstituteofMedicineoftheNationalAcademiesreport1999Medicalerrorskill44,000-98,000patientsinUShospitalseachyear.“Numberoneproblemfacinghealthcare”LucienLeape,HarvardProfessorofPublicHealthMedicalErrors2002CommonwealthFundreportestimatedthat22.8millionpeoplehaveexperiencedamedicalerror,personallyorthroughatleastonefamilymemberReinforcesthe1999IOMreport,“ToErrisHuman”Annualcostsestimatedat$17–29billionUSAgencyforHealthcareResearchandQuality(AHRQ)estimatemedicalerrorsarethe8thleadingcauseofdeathintheUS–higherthan:MotorVehicleAccidents(43,458)Cancer(42,297)AIDS(16,516)LaboratoryErrorsAreviewoftheliteraturefoundthemajorityoferrorsoccurinthepreandpostanalyticalphases.
BoniniP,PlebaniM,CeriottiF,RubboliF.ClinChem2002;48:691-698.Manymistakesarecalled“l(fā)aberror”,butactuallyduetopoorcommunication,actionsbyothersinvolvedinthetestingprocess,orpoorlydesignedprocessesoutsidethelab’scontrol.Medicalerrorsoccurinprevention,diagnosisanddrugtreatmentoccur.Amongerrorsindiagnosis;50%werefailuretouseindicatedtests,32%werefailuretoactonresultsoftests,and55%involvedavoidabledelayindiagnosis.LeapeLL,BrennanTA,LairdN,etal.NEngJMed1991;324:377-84.7HistoricalQualityControlQualitycontrolhistoricallyusedtoreduceerrorsandpreventthereleaseofincorrectresultsfromthelaboratory!Bornfromthe1950’sindustrialmodelofqualityinanalyticalandfactoryprocessesQualitycontrolisastabilizedsurrogatesampleanalyzedlikeapatientsamplecontainingknownamountofmeasuredanalyte.IftheanalyticaltestsystemcanachievethedesiredresultusingaQCsample,thenthesystemisstableandqualitypatientresultsareassumedtobeproduced.8QualityControlAdvantagesQChastargetvalues,ifassayrecoverstarget,thensystemisassumedtobestable(instrument,reagent,operator,sample)ShiftinQC=Shiftinqualitypatientresults!WarnsoftestresultproblemsbeforereleasetophysicianQualityControlDisadvantagesIfQCnotanalyzedfrequentlyenoughorlabfailstotakeactionwhenQCfails,qualityofpatientresultsaffected!Withnewautoverificationorcontinuousreleaseofresultsbychemistryandhematologyanalyzers-PossibletoreleasepatientresultsbeforeaproblemisdetectedWhenaproblemisdetected,labmustgobackandreanalyzepatientssincelast“good”QCandpossiblysendoutcorrectedresults.Clinicalactioncouldbetakenonerroneousresultsintheinterimofcorrectinganunrecognizedissue!Despiteitslimitations,QCremainsanimportantmeansofdetectingandpreventinglaboratoryerrors!1011SystematicErrorsLiquidQCdoesagoodjobatdetectingsystematicerrors,like:ReagentdeteriorationorpreparationImproperstorageorshipmentconditionsIncorrectoperatortechnique(dilution,pipettesetting)Calibrationerrors–wrongsetpoint,factorsErrorswhichaffecteverytestinaconstantandpredictablemannerErrorsthatoccurfromonepointforwardorforalimitedperiodoftime12RandomErrorsLiquidQCdoesapoorjobatdetectingrandomerrorsunlesstheerrorspecificallyoccurswiththeQCsampleorincreasedresultvariabilityisnoted.Errorswhichaffectindividualsamplesinarandomandunpredictablefashion,like:ClotsBubblesInterferingsubstances13QCandLabErrorsQCQC09:0009:00LineLeak11:0001:15HemolyzedsampleQCdailyat09:00,twolevelsLineleakoccursat11:00,dispensespartialreagentcausing25%decreaseinvalues,notdetecteduntilnextdayQCat09:00.(SystematicError),mustreanalyzeallspecimenssincepreviousQCat09:00,thepreviousday.Hemolyzedspecimen(Randomerror)affectsonesample14HistoryofQualityControlQualitycontrolhasbeentraditionalmeansofmanagingerrorinthelaboratory!CLIA’67–requireddailyQCasintegralpartoftestingprocessCLIA’88-reaffirmed“twolevelsofQCpertestperday”(bloodgasesevery8hours)CAPadvocatesdailyQCthroughinspectionandaccreditationTheJointCommissionfocusesonpatientsafetyandpreanalytic,analyticandpostanalyticprocessesISOQCRecommendations15ISO15189–5.6.1Thelaboratoryshalldesigninternalcontrolsystemsthatverifytheattainmentoftheintendedqualityofresults.Specialattentionshouldbepaidtoeliminationofmistakesintheprocessofhandlingsamples,requests,examinations,reports,etc.Documentationshouldincludequalitycontrolproceduresbasedonmanufacturerinstructionsforuse.InternalQualityControl(internaltothelaboratory)isdefinedasasetofproceduresundertakenbylaboratorystaffforthecontinuousmonitoringofoperationandtheresultsofmeasurementsinordertodecidewhetherresultsarereliableenoughtobereleased.TheregularanalysisofQCmaterialscanserveasanessentialcomponentofalaboratory’sinternalcontrolsystem.16QualityinLaboratoryTestingDespiteanalyzingtheminimumrequired2levelsQC/day,wehaveallexperiencederroneouslaboratoryresults!QualityismorethanQC!Qualityis:TestingthatissafeandreliableAppropriateuseoftechnologytomeetmedicalneedsTestresultsthatcanbetrustedformedicalmanagementAlab’sreputationdependsonqualityofitsresults!Whatshouldbethelabgoalsforerrors?UnacceptableErrorsDeaths/106enplanements 0.2PPMDeaths/106generalanesthesiainductions 2-5Viraltransmissions/106transfusions 29Results>7SD/106automatedchemtests 100Lostbags/106airplanepassengers 5000Failures/106proficiencytests 14,000Difference>5%/106hematocrittests upto 190,000WitteD&VanNessS.FrequencyofUnacceptableResultsinPoint-of-CareTesting.ArchPatholLabMed123:761,1999SigmaMetricsSigmametricsareanindustrialmeasureofqualityinafactoryprocess
-estimatesrateofdefectsinproductsGoalofsigmametrics:ImprovecustomersatisfactionBalancenumberofrejectedproductswiththeincreasedcostrequiredtoimproveprocesses(tolowerdefectrates)SixsigmaconsensusforbalancingrejectionagainsttheincreasedcostsofimprovingerrorsforindustrialprocessesSixsigmawasadoptedandpopularizedintotheclinicallaboratoriesin1990’s18SigmaPerformanceNeedforQualityLaboratoryTestingLaboratorytestinginfluences>70%ofallmedicaldecisions.>7billionlabtestsconductedintheU.S.annually
SilversteinMD.Anapproachtomedicalerrorsandpatientsafetyinlaboratoryservices.AwhitepaperpreparedfortheQualityInstituteMeeting,MakingtheLaboratoryaPartnerinPatientSafety.DivisionofLaboratorySystems,CentersforDiseaseControlandPrevention,April2003./mlp/qiconference/
BeyondSixSigmaWith>7billiontestsconductedintheUSannually,sixsigma(3.4defects/milliontests)meansreleasing23,800incorrectlabtestsannuallyintheUS!
Anysingleresulterrorcouldmeanamisdiagnosis,failuretotreatanillnessorincorrecttreatmentselection!Viruscontaminationofbloodproduct,IncorrectcancerdiagnosisMissedheartattack!Whatifthatwrongtestresultbelongedtoyouorafamilymember?Foramedicallaboratory,sixsigmaisanunacceptablegoal!Weneedtogo“beyondsixsigma”forlaboratoryperformance,withagoalofZEROerrorsthatreachthepatient!2122RiskDefinitionRisk–thechanceofsufferingorencounteringharmorloss(Webster’sDictionaryandThesaurus,1993Landoll,Ashland,Ohio)RiskisthepotentialforanerrortooccurRiskDefinitionISO/IECGuide51–RiskcanbeestimatedthroughacombinationoftheprobabilityofoccurrenceofharmandtheseverityofthatharmRISK=(Frequency)x(SeverityHarm)x(Detection)↑numberoferrors=greaterrisk↑harm=greaterriskInabilitytodetectanerror=greaterriskRiskissimplyaratingscaletoranktheorderforaddressingpotentialerrorsinlab(withlimitedavailableresources)23MedicalErrorsThePersonEasiertoblameapersonthananinstitutionforerrors.Inaviation,90%ofqualitylapsesarejudgedtobeblameless.TheSystemActivefailuresduetopersonalinteractionwithsystemLatentconditions,weaknessesinsystemduetodesignflawsorheirarchicaldecisionsNeedtoengineersystemsthatpreventdangerouserrorsandareabletotolerateerrorsandcontaintheireffectsReasonJ.BMJ2000;320:768-770.IdentifyingRiskintheLaboratoryThereisno“perfect”device!AnydevicecanandwillfailundertherightconditionsEverydeviceisdifferent!(universal2levelsQC/daydoesn’tfiteverysituation,mayneedmorefrequentQC–especiallyiffrequentstaffturnoverorunstablereagent)Anydiscussionofriskmuststartwithwhatcangowrongwithatest(errors)Labtestsarenotfool-proof,forasufficientlytalentedfool!26CLSIProject:EP23LaboratoryQualityControlBasedonRiskManagement.JamesH.Nichols,Ph.D.,ChairholderEP23describesgoodlaboratorypracticefordevelopingaqualitycontrolplanbasedonmanufacturer’sinformation,applicableregulatoryandaccreditationrequirements,andtheindividualhealthcareandlaboratorysetting27EP23LaboratoryQCBasedon
RiskManagementMedicalRequirementsforTestResultsTestSystemInformation:ProvidedbythemanufacturerObtainedbytheLaboratoryInformationaboutHealthCareandTest-SiteSettingInputInformationProcessRiskAssessmentOutputLaboratoryDirector’sQCPlanPostImplementationMonitoringContinuousImprovementRegulatoryandAccreditationRequirementsCLSIEP23TableWhereistheRiskin
theProcess?28WhatCouldPossiblyGoWrong?IdentifyingRiskintheLaboratoryFollowthesamplethroughthetestingprocess!Ateachstep,ask“Whatcouldpossiblygowrong?”Foreachhazardidentified,defineamitigationstep,awaytominimizetheriskoferroroccurring!Summarizethehazardsandactionsinaqualitycontrolplan!29StepsoftheTestingProcessPatientNeedforTestOrderPatientPreparationSpecimenCollectionLabReceiptAnalysisResultVerificationAcknowledgeResultOrderTreatmentTreatmentPreanalyticalPostanalyticalTransporttoLabAnalyticalProcessingFishboneDiagramfromCLSIEP23…RefertoAppendixAinCLSIEP18formorecomprehensivelistoferrorsourcesSourcesofLaboratoryErrorTestSystem:Reagentcontamination,deterioration,lotvariationReactionfluctuationsInadequatesamplingImproperorlossofcalibrationElectronicormechanicalfailurePowersupplyEnvironment:TemperatureandairflowHumidityLightintensityAltitudeOperator:Improperspecimenprep,handlingIncorrecttestinterpretationFailuretofollowtestsysteminstructionsCLIAInterpretiveGuidelinesforLaboratories.AppendixC,SubpartK.§493.1256Standard:ControlProcedures.InterpretiveGuidelines§493.1256(a)–(c)./Regulations-and-Guidance/Legislation/CLIA/Interpretive_Guidelines_for_Laboratories.html
33RiskManagementHolisticorglobalapproachtoqualityassuranceincorporatingpreanalytic,analyticandpostanalyticphasesoftestingEveryinstrumentordeviceisdifferentHazardanalysisandmitigationHazardanalysisdefinesthesourcesofpotentialerrorforaninstrumentordevice
andameansofdetectingorpreventingtheerror(mitigation)34ManufacturerChecks–AlternativeQCSomedeviceshaveinternalcheckswhichareperformedautomaticallywitheveryspecimen:Developmentofaline(Pregnancytest,Occultblood)Sensorsignal(bloodgasanalyzer,clots)Flowresistanceandliquidsensors(clotsorbubblesinchemistryandhematologyanalyzerpipettes)Otherchecksengineeredintoinstrument:Barcodingofreagentexpirationdates(preventsuse)LockoutfeaturesthatrequiresuccessfulQCDisposableanalyzercuvettes/pipettetips(carry-over)Temperatureindicatorinshippingcarton35QCandRiskManagementAnalyzerReagentFluidics,pipetting,electronics,motorsSomeinternalchecksdetectmechanicalandelectronicfailuresChemistryofreactionIntricatelylinkedwiththeanalyzerSusceptibletoenvironmenteffects36QCandRiskManagementTwolevelsofQCeachday,detectserrorsfrommanysourcesAnalyzer(pipets,mechanical,electrical)Reagent(storage,drift)Operator(calibration,dilution)Environment(reagentandsample)Automatedanalyzershavemanypartsandsourcesoferror,notallofwhicharedetectedbyinternalchecks.QCdoesagoodjobofdetectingsystematicerrorsthatpersistintime,butmayfailtodetectrandomerrorsoccurringwithsinglesamples.Randomerrors,likehemolysis–requiresserumindicesonchemanalyzer,visualsampleinspectionand/orphlebotomisttrainingforsamplecollectionissues37PointofCareQCandRiskManagementDeviceTestCartridgeReadstestcartridgesignalInternalelectronicchecksmaintainreaderwithinnarrowspecificationsChemistryofreactionContainsfluidics,calibrant,internalQC38QCandRiskManagementDeviceOnlyreadssignalElectronicscheckenvironment(temp)anddeviceintegrityLocksouttestingwhenoutsidespecificationsTestCartridgeActsastheanalyzerRiskfromenvironmentandoperatoreffectsQConcartridgeevaluateschemistrywitheachtestAdditionalcontrolprocessesforsampleandforoperatortechnique39QCandRiskManagementQCisexpensive,consumesreagentandlaborwithoutproducingresultsthatcanbebilled.ThepresenceofengineeredcontrolprocessesonnewerPOCTdevicesraisethequestionofwhenandhowthesecontrolscansubstitutefortwolevelsofliquidQC?Howtobestcontrolunit-usePOCTdevices?LabDirectormustbalancerequirementsforQC(2levels/day)againstcostandavailabilityofalternativecontrolswithinthetestsystemRiskmanagementandwalkingthroughthetestingprocesstoidentifyhazardsandsourcesoferrorcanhelplabsidentifytherightbalanceofliquidQCwithengineered-builtincontrolprocessesonthedevicesIndividualizedQualityControlPlanIndividualizedQualityControlPlanRiskAssessmentQualityControlPlanQualityAssessment40CLIANewIQCP
CLIA,CAPandJointCommissionRequirementsTwolevelsofliquidQCrequiredeachdayoftesting
ORLaboratorydevelopsanIndividualizedQualityControlPlan(IQCP):Balancebuilt-incontrolprocesseswithliquidQCReducefrequencyofliquidQCtominimumrecommendedbymanufacturerMaximizeclinicaloutcome,availablestaffresourcesandcosteffectivenessinthelabConsidersthelaboratoryprocessfortestingandriskoferrorsateachstepofthetestingprocess!41WhatHaveWeLearnedFromOurIQCP?QCwasexcessive.Past,i-STAT,QCthedevice(x27i-stats)-separatetestsystemsLotshipments(testoneachdevice)MonthlyQCcartridges(oneachdevice)6monthcorrelations/linearities(eachdevice)BUT…Chemistryisinthecartridge–shouldvalidateeachlotofcartridgesusingsubsetofi-stats(whicharejustreaders)Rotatei-statsHighmidandlowQClevelssameas3vialsinlinearityset–sodon’tneedtopurchaseseparatelinearity42Before:(QCthedevice)Shipments= 3QCx5daysx6x/yr= 90testsQCmonthly= 3QCx27i-stats= 81testsLinearities= 27i-statsx3levelsx3repsx2x/yr= 486tests6mocorrelations=10patientsx27i-stats= 270tests
TOTAL= 927testsAfter:(QCthecartridges,centralizedshipments)Shipments= 3QCx6x/yr= 30testsQCmonthly= 3QCx5lotcartridges(max)x12=
180testsLinearities= alreadydonemonthlyasQC= 0tests6mocorrelations=5pts/shipmentx2old/newx6x/yr= 60tests TOTAL=270testsSavingsof657cartridgesperyear43WhatHaveWeLearnedFromOurIQCPs?FalselyDecreased
GlucoseMeterResultsComplaintfromanintensivecareunitofsporadicfalselydecreasedglucosemeterresultsImmediaterepeattestonsamemeter,gavesignificantlyhigher“clinicallysensible”valuesInspectionofunitfoundnursestakingproceduralshortcutstosavetimeBottlesofteststripsdumpedoncounterinspareutilityroomSomestripsnotmakingitintotrash,fallingbackoncounterandbeing“REUSED”44RiskofErrorfrom
OpenReagentsGlucoseteststripsexposedtoairforaslittleas2hourshavebeenshowntocause-26%bias.1Stripsleftoncountersposeriskofreuse,leadingtofalselylowresults.Somemeterscatchreuseand“error”preventingaresult.Othermetersdonot!245KefferP,KampaIS.Diabetes1998;47;abs0170.SilvermanBC,HumbertsonSK,StemJE,NicholsJH.Operationalerrorscauseinaccurateglucoseresults.DiabetesCare2000;23:429-30.ReagentErrors:ExpiredReagentsCentersforDiseaseControl“Checkandrecordexpirationdatesofreagents/kits,anddiscardanyreagentsorteststhathaveexpired.”1U.S.FoodandDrugAdministration“Checktheexpirationdateonthet
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 綠色低碳數(shù)字化新型園區(qū)污水處理廠項目可行性研究報告模板立項申批備案
- 2025合作協(xié)議樣本
- 2025年春季部編版初中數(shù)學(xué)教學(xué)設(shè)計八年級下冊第1課時 平行四邊形的判定 1
- 攝像課基礎(chǔ)知識培訓(xùn)課件
- 2025年版動產(chǎn)與不動產(chǎn)抵押合同模板
- 公司股權(quán)稅務(wù)知識培訓(xùn)總結(jié)
- 公司組織安全知識培訓(xùn)課件
- 插花入門基礎(chǔ)知識培訓(xùn)課件
- 制造業(yè)崗位面試題及答案
- 2025濟南市房屋租賃合同中介版
- 酒店客房樣板間裝修驗收記錄表
- 2024年高級統(tǒng)計實務(wù)考試真題及答案解析
- 鐵總物資〔2015〕250號:中國鐵路總公司物資采購異議處理辦法
- GB/Z 42625-2023真空技術(shù)真空計用于分壓力測量的四極質(zhì)譜儀特性
- 人民醫(yī)院心血管外科臨床技術(shù)操作規(guī)范2023版
- 助理工程師考試試題以及答案
- 送東陽馬生序
- 2017年全國大學(xué)生數(shù)學(xué)建模A題
- 2023年專升本計算機題庫含答案專升本計算機真題
- GB/T 16674.1-2016六角法蘭面螺栓小系列
- 住宅項目景觀工程施工策劃(圖文并茂)
評論
0/150
提交評論