Designation:E1977-24
StandardSpecificationfor
Shelter,Tactical,Expandable,One-Side1
ThisstandardisissuedunderthefixeddesignationE1977;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginaladoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.A
superscriptepsilon(E)indicatesaneditorialchangesincethelastrevisionorreapproval.
ThisstandardhasbeenapprovedforusebyagenciesoftheU.S.DepartmentofDefense.
1.Scope
1.1Thisspecificationcoversarigidwall,one-sideexpand-ableshelterconstructedofaluminum-faced,nonmetallichon-eycombsandwichpanels,andmeetingtheInternationalOrga-nizationforStandardization(ISO)CargoContainerspecificationinthetransportmode.Nominaldimensionswhenclosed(containermode)are:height8ft,width8ft,andlength20ft(2.4mby2.4mby6.1m).Approximatedimensions,whenexpanded(sheltermode)are:height8ft,width15ft,andlength20ft(2.4mby4.6mby6.1m).
1.2Thevaluesstatedininch-poundunitsaretoberegardedasstandard.ThevaluesgiveninparenthesesaremathematicalconversionstoSIunitsthatareprovidedforinformationonlyandarenotconsideredstandard.
1.3Thefollowingprecautionarystatementpertainstothetestmethodportiononly.Section7,ofthisspecification;Thisstandarddoesnotpurporttoaddressallofthesafetyconcerns,ifany,associatedwithitsuse.Itistheresponsibilityoftheuserofthisstandardtoestablishappropriatesafety,health,andenvironmentalpracticesanddeterminestheapplicabilityofregulatorylimitationspriortouse.
1.4Thisinternationalstandardwasdevelopedinaccor-dancewithinternationallyrecognizedprinciplesonstandard-izationestablishedintheDecisiononPrinciplesfortheDevelopmentofInternationalStandards,GuidesandRecom-mendationsissuedbytheWorldTradeOrganizationTechnicalBarrierstoTrade(TBT)Committee.
2.ReferencedDocuments
2.1ASTMStandards:2
E864PracticeforSurfacePreparationofAluminumAlloys
toBeAdhesivelyBondedinHoneycombShelterPanels
1ThisspecificationisunderthejurisdictionofASTMCommitteeE06onPerformanceofBuildingsandisthedirectresponsibilityofSubcommitteeE06.53onMaterialsandProcessesforDurableRigidwallRelocatableStructures.
CurrenteditionapprovedJuly1,2024.PublishedAugust2024.Originally
approvedin1998.Lastpreviouseditionapprovedin2018asE1977-18.DOI:
10.1520/E1977-24.
2ForreferencedASTMstandards,visittheASTMwebsite,
,or
contactASTMCustomerServiceat
/contact.ForAnnual
BookofASTMStandardsvolumeinformation,refertothestandard'sDocumentSummarypageontheASTMwebsite.
E865SpecificationforStructuralFilmAdhesivesforHon-
eycombSandwichPanels
E866SpecificationforCorrosion-InhibitingAdhesive
PrimerforAluminumAlloystoBeAdhesivelyBondedin
HoneycombShelterPanels
E874PracticeforAdhesiveBondingofAluminumFacings
toNonmetallicHoneycombCoreforShelterPanels
E990SpecificationforCore-SpliceAdhesiveforHoney-
combSandwichStructuralPanels
E1091SpecificationforNonmetallicHoneycombCoreforUseinShelterPanels
E1749TerminologyRelatingtoRigidWallRelocatableShelters
E1773PracticeforSealingRigidWallTacticalShelterswith
PolysulfideBasedSealants
E1826SpecificationforLowVolatileOrganicCompound
(VOC)Corrosion-InhibitingAdhesivePrimerforAlumi-numAlloystoBeAdhesivelyBondedinHoneycombShelterPanels
E1925SpecificationforEngineeringandDesignCriteriaforRigidWallRelocatableStructures
2.2ANSI/ASQStandard:3
ANSI/ASQZ1.4-2003(R2018)SamplingProceduresand
TablesforInspectionbyAttributes
2.3AWSStandard:4
AWSD17.1/D17.1MSpecificationforFusionWeldingofAerospaceApplications
2.4ISOStandards:5
ISO1161:2016Series1FreightContainers-CornerandIn-termediateFittings-Specifications
ISO1496-1:2013Series1FreightContainers-SpecificationandTesting-PartI:GeneralCargoContainersforGeneral
Purposes
ISO9001QualityManagementSystems-Requirements
3AvailablefromAmericanSocietyforQuality(ASQ),600N.PlankintonAve.,Milwaukee,WI53203,
.
4AvailablefromAmericanWeldingSociety(AWS),8669NW36St.,#130,Miami,FL33166-6672,
.
5AvailablefromAmericanNationalStandardsInstitute(ANSI).25W.43rdSt..
4thFloor,NewYork,NY10036,
.
Copyright◎ASTMInternational,100BarrHarborDrive,POBoxC700,WestConshohocken,PA19428-2959.UnitedStates
2.5MilitaryStandards:6
MIL-STD-129MilitaryMarkingforShipmentandStorageMIL-STD-810HEnvironmentalEngineeringConsiderations
andLaboratoryTests
2.6Drawings:7
5-4-2828Shelter,Assembly,One-SideExpandable-60amp
5-4-3200Shelter,Assembly,One-SideExpandable-100amp
3.GeneralRequirements
3.1AlternateComponents—Whenthisspecificationorthereferenceddrawingsspecifyuseofaspecificcomponent"orequal,"thecontractormaysubstituteacomponentequaltothespecifiedcomponentprovidedthatthecontractorcomplieswiththefollowingrequirements.Priortomanufactureofthefirstarticle,orifnoneisrequired,priortocommencingproduction,thecontractorshallsubmitforthepurchaser'sapprovalalistidentifyingeachproposed“orequal”componenttogetherwithproofthateachlistedcomponentisfunctionallyequaltothespecifiedcomponentandiscompatiblewiththeenditemcoveredbythisspecification.Thepurchaser,athisoption,mayrequireaphysicalsampleofany“orequal”component.Approvalofthesubmittedlistingandsupportingdataauthorizesthecommencementoffabricationofthefirstarticleorofproduction,asapplicable,butdoesnotrelievethecontractoroftheresponsibilitythatthe“orequal”componentsperforminaccordancewithspecifiedrequirementswhenincorporatedintotheenditem.
3.2MaterialsandComponents—MaterialsandcomponentsshallconformtothedocumentslistedinSection2andasspecifiedherein.Anychangetotheproposedmaterialsorprocessesmustbeapprovedbythepurchaser.Itisencouragedthatrecycledmaterialbeusedwhenpracticalaslongasitmeetstherequirementsofthisspecification.
3.3Workmanship—Theshelter,includingallpartsandaccessories,shallbeconstructedandfinishedinaworkmanlikemannerwithparticularattentiongiventoremovalofburrsandsharpedges,accuracyofdimensions,thoroughnessofsoldering,welding,painting,alignmentofpartsofassemblies,andthetightnessofscrews,bolts,andsoforth.Gasketsshallnotbetornorsplitandshallbefreeoffinish.Clothcompo-nentsshallbecleanandfreeofholes,cuts,ortears.Alllatchesutilizedforerectionandclosingofthesheltershallbeproperlyadjustedbeforetheshelterispreparedfordeliverytothepurchaser.
3.4Riveting—Rivetingjointsshallbetight.Thejoinedpartsshallbeundamaged,andtherivetheadsshallbeproperlyseatedandtightagainstthebearingsurfaces.Alltherivets,exceptthoseusedinpanelbonding,shallbedippedinpolysulfidesealantjustpriortoinsertion,however,adabofpolysulfidesealantshallbeappliedtotheheadofeachrivet.
3.5Cleaning—Afterfabrication,partsshallbecleanedinaccordancewiththedrawings.
?AvailablefromDLADocumentServicesCustomerSupportCenterat1-866-736-7010,
.
7CopiesofdrawingsareavailablefromU.S.ArmyDEVCOMSoldierCenter,ATTN:FCDD-SCD-SXD,15GeneralGreeneAvenue.Natick.MA01760-5056.
/centerslabs/sc/.
3.6Welding—Weldedjointsshallbesuchthatgrindingofthefinishedweldshallnotbearequirement,exceptwhenspecifiedonthedrawing.Spot,stitch,andseamweldsshallbeasindicatedonthedrawings.Allsurfacestobeweldedshallbecleanedandfreefromscale,paint,grease,andotherforeignmaterials.Weldsshallhavethoroughpenetration,goodfusionandshallbefreefromscabs,blisters,abnormalpockmarks,cracks,voids,slaginclusions,andotherharmfuldefects.Weldedassembliesshallbecleanedtoremoveanyscale,oxidationproducts,andexcessflux.Anyacidusedincleaningshallbecompletelyneutralizedandremoved.WeldersshallbecertifiedinaccordancewithAWSD17.1/D17.1M.WeldingequipmentandproceduresshallconformtoAWSD17.1/D17.1M.
3.7Finish—Coatingsshalllevelouttoanadherent,continu-ousanduniformfilmwithoutruns,wrinkles,streaks,orareasofnofilm.Anycoatingdamagedduringassemblyorexami-nationshallbetouchedup.Thereshallbenoareasofrust.Finishshallbefreeofblistering,peelingandchips.
3.7.1AdhesionofPaint—Thesheltershallbecapableofwithstanding,withoutdegradationtothefinish,thetestsasspecifiedin7.37.Aftertopcoatapplication,theshelterinthedeployedmodeshallbestoredforaminimumof168hataminimumof70°F(21℃)priortoperformingthistest.
3.7.2Color—Thecolorofthepaintfilmshallbecomparedwithanappropriatecolorchipforthepaintspecified.
3.7.3Thickness—Thicknessofthepaintfilmshallbecheckedasspecifiedin7.39.
3.8FinishandColor—Surfacesshallbeofthecolor,treatment,andfinishasshownonthedrawings.Topcoatpaintingshallbeperformedonthefullyassembledsheltersoastopreventmismatchofcolorshading,unlessothercontroltechniquesareapprovedbythepurchaser.Aftertopcoatapplication,theshelterinthedeployedmode(thatis,ex-panded)shallbestoredina70°F(21℃)minimumtempera-tureindoorfacilityforaminimumof36htoensureadequatecoating(s)cure.Duringthisstorageperiodtheshelterdoorsandventsshallbeopenedtopermitaircirculationwithintheshelter.
3.9Manuals—Unlessotherwisespecified(see13.2),tech-nicalmanualsshallbeprovidedwitheachshelter.Stowageprovisionforthemanualsshallbelocatedasshownontheapplicabledrawings.
3.10TerminologyrelatedtothisspecificationisdefinedinTerminologyE1749.
4.DesignandConstructionRequirements
4.1DesignandConstruction—Designandconstructionoftheexpandablesheltershallconformtotherequirementsspecifiedonthedrawings,allsubsidiarydrawingsandpartslistsandhereinafter.Thesheltershallbefreeofpaneldelami-nationsandshallmeetallphysicalandenvironmentalrequire-mentsspecifiedherein.
4.2ContainerMode—Theshelterintheclosedortransportmodeshallbereferredtoasacontainer,hereinafter,forthepurposeofdefinition.Theshelter,inthecontainermode,shallbeanarticleoftransportequipmentmeetingISOfreight
TABLE1ContainerOverallDimensions
Type
Height
Width
in.
ft
in.
Length
Tol.
in.
ft
in.
Tol.
in.
ft
in.
Tol.
IC
8
(2.438
m)
0
+0
+0
-0.1875
(-5mm)
8
(2.438
m)
0
+0
+0
-0.1875
(-5mm)
19
(6.058m)
10.5
+0
+0
-0.25
(-6mm)
containerrequirementsrelatedtocargocontainers.Thesheltershallshownostructuraldamagewhentestedasspecifiedin7.20,7.22,7.23,and7.28-7.35andshallshownoleakagewhentestedasspecifiedin7.24,and7.24.1-7.24.3.ThecontractorshallensurethattheshelterreceivesCoastGuardCertificationforISOContainers.Thecontaineroveralldimen-sionsshallbeinaccordancewithISOfreightcontainerdesignatedICandareasshowninTable1.
4.3Panels—Thepanelsusedasstructuralmembersinthecontainerconfigurationshallmeetstructurallyalltransporta-tionandenvironmentalrequirementsspecifiedherein.Eachpanelshallbefabricatedasanetpanelwithaluminumextrusionsbondedaboutthepanelperimeterduringpanelbonding.Theinnerandouterskinsonalljointsshallbesealedtoprovideawaterbarrieragainsttheentranceofmoisturetothecorematerialandtotheinterioroftheshelter.Thewaterbarrieristobemaintainedintactatallpanelcross-sectionalopenings.Alljointsandedgesshallbeassembledandsealedinamannertopreventcollectionandretentionofmoisture.Particularemphasisshallbeplacedonthesealingofallmiteredcorners.
AlloftheabovesealingproceduresshallbeaccomplishedinaccordancewithPracticeE1773.
Rivetshaftsshallbecoatedwithsealingcompoundbeforeinsertion.Thesealershallbeasindicatedonthedrawings.Thecontractorshallhavetheappropriateequipmentandfacilities,usethecorrectproceduresinaccordancewithPracticesE874andE864,andusequalifiedpanelcomponents(thatis,struc-turalfilmandcorespliceadhesives,corrosion-inhibitingadhe-siveprimer,structuralnonmetallichoneycombcore,andasspecified5052-H34or6061-T6aluminumskins,FRPbarrierstrips,6061-T6panelextrusions).Priortouse,allcriticalpanelcomponentmaterialsmustbequalifiedinaccordancewithSpecificationsE865,E866,E990,E1091,andE1826.Thereshallbenoskinsplicesinthepanelsexceptwherenotedonthedrawings.Unlessotherwisespecified(see13.2),priortoawardofcontract,thecontractorshallsubmittothepurchaseracertifiedcopyofalaboratorytestreportandacopyoftheirprocessspecificationcoveringfabricationofthemetallic-faced,nonmetallichoneycombcoresandwichpanelstheyproposetouseintheconstructionoftheenditem.Usingtheirprocessspecification,thecontractorshallfabricatequalifica-tiontestsandwichpanelsandstructuralfilmadhesivefloatingrollerpeeltestspecimens,andshallperformtestsinaccor-dancewithSpecificationE865andPracticeE874(see13.2).
4.3.1PanelProcessing—Theshelterpanelsshallbepro-cessedandinspectedasspecifiedinPracticeE864andSpeci-ficationsE865,E866,orE1826dependinguponwhichprimerisbeingused,SpecificationsE990andE1091,andPracticesE874andE1773.Theshelterpanelsshallbeinspectedfor
dimensionsandflatnessinaccordancewiththe"DimensionalandFlatnessInspectionofPanel”SectionofPracticeE874(see10.2).
4.3.2PanelWatertightness—Panelassembliesshallnotper-mittheentryofwater(see10.3.1)whentestedasspecifiedin7.18.
4.3.3ResistancetoThermalShock—Panelsshallberesis-tanttothermalshock,whentestedasspecifiedin7.6.
4.3.4PanelInterchangeability—Allpanelsandpanelas-sembliesbearingsamepartnumbersshallbefunctionallyanddimensionallyinterchangeablewithoutmodificationorrework.Individualassembliesshallnotbehandpickedforfitorperformance,whentestedasspecifiedin7.7.
4.3.5Delaminations—Delaminationsinshelterpanelsshallbetestedasspecifiedin10.3.3.
4.3.6PanelFrameAirtightness—Weldedpanelframesshallbeairtightwhentestedasspecifiedin10.3.4.
4.4Inserts—Whentestedasspecifiedin7.8,thefollowingsizedinserts,whereused,shallwithstandthetorqueandpulloutloadsasspecifiedinTable2,withoutfailureoftheinserts,panel,orpottingcompound.
4.5Payload—Theunitisdesignedtocarryamaximumpayloadof94801b(4300kg)duringtransport.
4.6CornerFittings—Thecontainershallbeequippedwithcornerfittingsatthetopandbottomcornersinaccordancewiththedimensionalrequirementsforcornerfittingsforseries-1freightcontainersasstipulatedinISO1161requirementsforcommercialcontainers.Theupperfacesofthetopcornerfittingsshallprotrudeabovethetopoftherestofthecontainerbyaminimumof/4in.(6mm)ThelowerfacesofbottomcornerfittingsshallprotrudebelowthebottomofthecontainerbyaminimumofV16in.(11mm).
4.7ShelterMode—Theshelterintheerectedmodeshallbereferredtoasashelterhereinforthepurposeofdefinition.Hingedshelterpanelsshallbeattachedinamannertoensurecompliancewiththeenvironmentaltestrequirementsasspeci-fiedin7.6,7.13-7.17,7.24,and7.26.
4.8ExteriorLighting—Onearealightingfixture,asshownonthedrawings,shallbeprovidedwitheachshelter.
TABLE2InsertStrength(ProofLoads)
InsertPull-out,Ib(kN)Torque,ft-Ib(N·m)
4.9ShelterElectricalSystem:
4.9.1General—Thesystemshallhaveallequipment,ca-blingandotherhardwarenecessarytoreceivethreephase120/208V,60Hzpowerfromthebaseelectricaldistributionsystems,anddistributeittolightingfixturesandreceptaclesasindicatedonthedrawings.The60AsheltersshallbeinaccordancewithDrawing5-4-2828andallsubsidiarydrawingsandpartslists.The100AsheltersshallbeinaccordancewithDrawing5-4-3200andallsubsidiarydrawingsandpartslists.Allpartsoftheelectricalsystemshalloperatewhentestedforelectricalcontinuityasspecifiedin7.40.
4.9.2OperatingTemperature—Thewiringsystemandallindividualhardwareitemsshallbecapableofoperatingattheirrequiredcapacitywithinanambienttemperaturerangeof-60°Fto125°F(-51℃to52℃),exceptthatthefluorescentlightsshalloperatefromOFto125F(-18℃to52℃),whentestedasspecifiedin7.14and7.15.
4.9.3CurrentRating—Allconductorsandappropriatehard-wareshallberatedforcurrentcarryinginaccordancewiththeapplicableindustrystandardsasspecifiedonthedrawings.Deratingofcomponentsmaybenecessaryforanoperatingambienttemperatureof125°F(52℃).
4.9.4Finish—Panelboardsandallotherexposedmetallicitemsshallhavefinishesasindicatedonthedrawings(see3.7).
4.9.5PanelBoard—Thepanelboardusedshallbeasindicatedonthedrawings.Itshallbeofdeadfrontconstructionandhaveasolidneutralbus,agroundbus,anda60Aor100Athreephasemainbreakerasspecified(see13.2).ThepanelwillhaveaNEMA-1enclosurewithconduithubsasnecessaryandatleast18breakerspacesexcludingthemainbreaker.Thepanelboardbusfeedshallbebyrigidconduitandconductors;theconductorshavingacurrentcarryingcapacityofatleast
100Aat125F(52℃)ambienttemperature.Thebusfeedcablesshallterminateinaconnectormountedontheexterioroftheshelter.Conductorsrunningfrompanelboardcircuitstofixturesorreceptaclesshallbeenclosedinrigidconduitorshallbespecifiedflexiblecablefortheexpandableportionoftheshelter.Thecurrentcarryingcapacityoftheconductorsshallbe20Aminimum,baseduponanambienttemperatureof125°F(52℃)andNECratingprocedures.Allcircuitbreakersusedinthesystemshallbebolt-ontypeandhaveaminimuminter-ruptingcapacityof10000ARMSsymmetrical.
4.9.6Cabling—Flexiblecablesshallbeusedtofeedallrelocatablelightingfixturesandreceptacles.Thesecablesshallbeasindicatedonthedrawings.
4.9.7Switches—Switchesusedshallbeasindicatedonthedrawings.
4.9.8Grounding—Allnoncurrentcarryingmetalcompo-nentsshallbesolidlygroundedusingthegreengroundwirewithinthewiringsystem,asindicatedonthedrawings.
4.9.9Receptacles:
ElectricalPowerServiceEntrance—Theelectricalpowerserviceentranceshallbeasshownonthedrawings.
ConvenienceOutlets—Thesheltershallcontaindu-plexconvenienceoutletsasindicatedonthedrawings.Alloutletsshallbeelectricallygrounded.
AirConditioning—Powerforheatingandcoolingequipmentshallbeprovidedfromthedistributionpanelinthe
sheltertoanelectricalconnectormountedintheserviceentrancerecessedpanontheoutsideoftheshelterasindicatedonthedrawings.
ExternalOutlets—Powerdistributionshallbepro-videdfromthedistributionpanelboxinthesheltertooutletsmountedintheserviceentrancerecessedpanontheoutsideoftheshelterasindicatedonthedrawings.
4.9.10Communications—Thesheltershallhavefour(twopairs)circuitsthroughthewalltelephoneandintercomutilityconnectionsterminatinginfourprotectedterminalsinsideandoutsidetheshelter,asindicatedonthedrawings.
4.9.11Tools—Toolsprovidedwiththesheltershallberead-ilyaccessibletopersonnelwhentheshelterisinboththecontainerandshelterconfiguration.
4.10NameplatesandProductMarking—Allmarkingsshallconformtothedrawings.Eachsheltershallbeseriallynum-beredandprovidedwithanameplateinaccordancewithapplicabledrawings(see13.2).
4.10.1InteriorMarkings—Interiormarkingsshallbeasshownandinthelocationsshownontheapplicabledrawings.
4.10.2ExteriorMarkings—Thesheltershallbeprovidedwithspecificexteriormarkingsasshownontheapplicabledrawings.
5.PerformanceRequirements
5.1FloorLoads—Theshelterfloorshallbecapableofsupportingauniformloadof651b/ft2(320kg/m2).Theshelterfloorshallbecapableofsupportingaconcentratedloadof20001b(910kg)overa4ft2(0.4m2)areaatthecenterofthefloor.Thefloorshallalsobecapableofsupportingapointloadof1251b/in.2(9kg/cm2).Loadsshallnotcauseanypermanentdeformationofthefloorsorcauseanydeflectionthatinterfereswithpropershelteroperation,whentestedasspecifiedin7.9.
5.2RoofLoads—Theroofassemblyofthesheltershallwithstandasnowloadof401b/ft2(200kg/m2)andapersonnelloadof6601b(300kg)staticover2ft2(0.2m2)whentestedasspecifiedin7.10.
5.3DoorLoads—Containerdoorsshallbetestedtowith-standthefollowingloadswithoutdeformationorimpairmentoffunction:
5.3.1StaticDoor(Hinge)Load—Thedoors,frames,andhardwareshallbecapableofsupporting2001b(90kg)appliedtothedoorattheedgeoppositethehingepivotlinewiththedooropentoapproximately90°whentestedasspecified7.11.
5.3.2WindGustDoor(Stop)Load—Thedoors,frames,andhardwareshallwithstandawindgustof60mph(100km/h)inanydirectionwhenthedoorissecuredinitsopenpositionbyitsdoorstopdevicewhentestedasspecifiedin7.11.
5.4StepAssembly—Thecompletelymountedstepassemblyshallwithstandaverticalloadof5001b(225kg)appliedtotheoutersectionwithoutdeformationoftheassemblyofsupport-ingstructurewhentestedasspecifiedin7.12.
5.5Airtightness—Thesheltershallnotpermitairleakagebeyondspecifiedlimitsineithercontainerorshelterconfigu-rationwhentestedasspecifiedin7.13.
5.6TemperatureRange:
5.6.1Non-operatingTemperature—Thecontainermodeconfigurationshallwithstandexposuretoatemperaturerangeof-60Fto160F(-51℃to71℃).
5.6.2OperationalTemperature—Thesheltershallbede-pendableandoperableinanambienttemperaturerangeof-60F(exceptelectrical(see4.9.2))to125F(-51℃to52℃)plusasolarloadsuchthattheouterskinreachesatemperatureof200°F(93℃),whentestedasspecifiedin7.14,7.15,and7.26.
5.7HumidityandTemperatureAging(Components)—Thesheltercomponentsshallbecapableofwithstandingtheconditionsofaminimum95%relativehumidityat200°F(93℃).Thereshallbenoevidenceofdelamination,cracking,corrosion,ordeteriorationwhentestedasspecifiedin7.16.
5.8Blackout—Thereshallbenointernallightvisiblefromoutsideoftheunitinthesheltermodewhentestedasspecifiedin7.17.
5.9InsertStrength—Whentestedasspecifiedin7.19,theinsertsindicatedinTable2shallwithstandloadsequalto80%oftheapplicablestrengthsshowninTable2withoutfailureandasindicatedinTable3.
5.10RailTransportability—Theshelterwhentestedasspecified(see7.20)shallbecapableofwithstanding,withoutdamage,theshocksnormallyinducedbyrailtransport.
5.11ImpactResistance—Theshelterpanelshallbeimpactresistantwhentestedasspecifiedin7.21.
5.12DropTest—Theshelterwhentestedasspecifiedin7.22shallshownoevidenceofdamageasaresultofthedroptest.
5.13Towing—Thesheltershallshownoevidenceofdam-agewhentestedasspecifiedin7.23.
5.14WaterLeakage—Thesheltershallshownoevidenceofleakagewhentestedasspecifiedin7.24.
5.15FluorescentLightTemperature—Shelterfluorescentlightassembliesshallshownofailurewhentestedasspecifiedin7.25.
5.16SolarLoad—Thesheltershallwithstandasolarloadtestwhentestedasspecifiedin7.26.
5.17OperationalFitness—Thesheltershallprovefunc-tionalwhentestedasspecifiedin7.27.
5.18HeatTransfer—Theoverallcoefficientofheattransferofthesheltershallnotexceed0.35BTUperhourpersquarefootperdegreeFahrenheit(2.0wattspersquaremeterperdegreeKelvin)(see7.36).
TABLE3InsertStrength(WorkingLoads)
InsertPull-out,Ib(kg)Torque,ft-Ib(J)
6.OtherRequirements
6.1Requirementsandtestingforlifting,six-highstacking,longitudinalrestraint,racking,lashing,endwallstrength,side-wallstrength,andliftingfromforkliftpocketsshallconformtoISO1496-1whentestedasspecifiedin7.28-7.35.
6.2FirstArticle—Whenspecified,asampleshallbesub-jectedtofirstarticleinspection(see8.1and13.3).
6.3InspectionComparisonTestingSample—Whenspeci-fied(see13.2),thecontractorshallfurnishasampleforcomparisoninspectionandapproval(see9.1and13.4).
6.4Manuals—Unlessotherwisespecified(see13.2),tech-nicalmanualsshallbeprovidedwitheachshelter.Stowageprovisionsforthemanualsshallbelocatedasshownontheapplicabledrawings.
7.TestMethods
7.1ElectricalContinuityTesting—Testeveryenditemasspecifiedin7.40.Anytestfailureshallbecauseforrejectionoftheenditem.
7.2WaterLeakageandOperationalTesting—Testthefirsttenproductionunitsasspecifiedin7.24,7.24.1and7.24.3.Ifnofailuresareexperienced,fiveofthenexttenproductionunitsshallbe
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 國際教育交流項目2025年學生跨文化心理調(diào)適與成長路徑研究
- 2025年新能源汽車制造產(chǎn)業(yè)技術(shù)創(chuàng)新與產(chǎn)業(yè)升級報告
- 醫(yī)療美容行業(yè)注射美容新技術(shù)應用與市場監(jiān)管策略研究報告
- 安徽省合肥市新城高升學校2026屆化學高一第一學期期末聯(lián)考試題含解析
- 傳統(tǒng)工業(yè)制造行業(yè)工業(yè)機器人與人工智能融合發(fā)展趨勢研究報告
- 公共衛(wèi)生應急物資資金申請在2025年公共衛(wèi)生事件中的物資保障策略
- 2025年文旅地產(chǎn)項目文化傳承與創(chuàng)新研究報告
- 醫(yī)療美容行業(yè)規(guī)范化發(fā)展與2025年市場監(jiān)管制度創(chuàng)新研究
- 中藥配方顆粒質(zhì)量標準優(yōu)化與市場拓展策略研究報告
- 新解讀《GB-T 39103 - 2020超細羊毛機織物標識 Super S代碼定義的要求》
- 齊魯名校大聯(lián)考2025屆山東省高三第七次學業(yè)水平聯(lián)合檢測語文試題及答案
- 鋼渣購銷合同協(xié)議
- 2025廣東高考:數(shù)學必考知識點歸納
- 降本質(zhì)量風險管理制度
- 嚴重過敏反應診斷和臨床管理專家共識(2025年版)解讀
- 股東糾紛和解協(xié)議書
- 2025年初中語文文言文150個??紝嵲~用法
- 鋼琴樂理四級試題及答案
- 企業(yè)財務審計與合規(guī)管理
- 淺談如何制定青少年籃球體能訓練方法
- 2025年度酒店布草洗滌消毒服務質(zhì)量協(xié)議
評論
0/150
提交評論