




已閱讀5頁,還剩27頁未讀, 繼續(xù)免費閱讀
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)
文檔簡介
HX-801B / HX-801C Infusion Pump Service ManualVersion :1.032目錄ContentsPart-1: HardwareI. Machine Disassembly Steps41. 產(chǎn)品外觀42. 使用工具或材料43. 注意事項44. 拆解步驟44.1. 拆電池44.2. 拆分前后殼44.3. 拆后殼電源板和通訊小板(C款無通訊小板)54.4. 拆前殼電機(jī)54.5. 拆前殼主板排線、喇叭、下端壓力傳感器板64.6. 拆前殼主板74.7. 拆前殼上/下兩個霍爾傳感器74.8. 拆前殼顯示屏84.9. 拆前殼后超聲波傳感器84.10. 拆前殼前超聲波傳感器94.11. 拆前殼蠕動泵94.12. 組裝方法9II. Machine Setup101. 電機(jī)工作點調(diào)試101.1. 目的101.2. 所需工具101.3. 機(jī)器設(shè)置101.4. 萬用表接法101.5. 工作點電平規(guī)格區(qū)分111.6. 調(diào)試方法112. 壓力標(biāo)定122.1. 目的122.2. 標(biāo)定方法123. 電池基準(zhǔn)點電壓標(biāo)定153.1. 目的153.2. 所需工具153.3. 標(biāo)定方法154. 超聲波傳感器更換后檢測164.1. 目的164.2. 所需工具164.3. 檢測方法16. Mainboard Circuit Diagram18IV. Accessories List19Part-2: SoftwareI. Mainboard Program Burning201. 所需物件清單202. 安裝燒錄軟件203. 燒錄主板程序24II. Mainboard Program Update28Part-3: Trouble Shooting & Maintance GuideI. Trouble Shooting291. 常見報警的排除方法292. 其它故障的排除方法303. 機(jī)器定期點檢的方法30II. Maintenance Guide311. 日常保養(yǎng)312. 內(nèi)部電池使用313. 電池充電314. 電池更換315. 定期更換部件326. 運輸和儲存32HX-801B/C拆解方法一:產(chǎn)品外觀HX-801B/C 正面圖 HX-801B/C 背面圖B型帶點滴傳感器C型則沒有-見圖片 二:使用工具或材料1. 大小十字螺絲刀各一個(必備) 2. 大小一字螺絲刀各一個(必備) 3. 內(nèi)六角螺絲刀一個(必備)4. 鑷子(必備)5. 醫(yī)用酒精(必備)6. 吹風(fēng)機(jī)一個(選用) 6. 電烙鐵一個(選用) 7. 熱熔膠槍及膠棒(安裝使用) 8. 膠水(選用)9. 扎帶(選用)10. 小刀(選用)12. 齒輪潤滑油(選用) 三:注意事項1. 拆機(jī)前請確保已斷開外電源;2. 機(jī)器輕拿輕放,請注意保護(hù),以防碰撞跌落損壞機(jī)器或人員意外受傷;3. 注意提供必要的靜電防護(hù)措施;4. 注意拆解后零部件的防護(hù)工作,以防損壞或遺失;5. 說明:本指導(dǎo)所附圖片上的所有紅色圓圈代表螺絲固定連接,紅色方框代表接線位置或結(jié)構(gòu)件安裝位置, 紅色箭頭代表拆解作業(yè)示意方向。四:拆裝步驟1. 拆電池(此處可更換電池):(1) 如下圖所示將產(chǎn)品背面朝上放平,用螺絲刀將固定電池蓋板的固定螺絲取出;(2) 用手將電池線依次從主板上拔出;(3) 取出電池。 2. 拆分前后殼:(1) 用螺絲刀將固定前后殼的4顆固定螺絲取出;(2) 將前后殼反向分開(因接合處內(nèi)置防潮線-受潮變粘可有效防止潮氣進(jìn)入到機(jī)器內(nèi)部,如果無法直接用手分開,可用吹風(fēng)機(jī)對著前后殼接合處環(huán)繞一周吹一定時間(或用醫(yī)用酒精浸濕),使防潮線變干失去粘性,這樣前后殼更易分開);(3) 用手將主板電源線從主板插座上拔出;(4) 再用手將通訊排線分別從前殼主板及后殼通訊小板(僅B款)上的插座內(nèi)拔出,然后分開前后殼。 3. 拆后殼電源板和通訊小板(僅B款才有,C款沒有通訊小板)(此處可更換電源板和通訊小板):(1) 用螺絲刀將外源插座的2顆固定螺絲取出;(2) 再用螺絲刀將電源板絕緣墊的6顆固定螺絲取出,然后將絕緣墊拿開;(3) 再將電源板的1顆固定螺絲取出,將電源板拿開放好;(4) 再將通訊小板的3顆固定螺絲取出,將通訊小板拿開放好(此項僅適用于B款)。 4. 拆前殼電機(jī)(此處可更換電機(jī)-如只需更換維修主板或顯示屏及控制板或按鍵面板的話可不拆電機(jī)):(1) 將電機(jī)排線從主板插座上拔出;(2) 用螺絲刀將固定主板和電機(jī)的1顆固定螺絲取出;(3) 再用螺絲刀將電機(jī)的2顆固定螺絲取出,然后將電機(jī)拿下來。5. 拆前殼主板排線、喇叭、下端壓力傳感器板(此處可更換喇叭和下端壓力傳感器板):(1) 用螺絲刀將電機(jī)面端霍爾傳感器排線和前超聲波傳感器排線固定膠帶的1顆固定螺絲取出;(2) 再將電機(jī)面主板上所有排線從主板插座上拔出;(3) 將主板另一面的按鍵面板排線和喇叭排線從插座上拔出,再將喇叭從插槽內(nèi)取出;(4) 用螺絲刀將下端壓力傳感器板的2顆固定螺絲取出,然后將下端壓力傳感器板拿下來。下端壓力傳感器排線電池排線下端霍爾傳感器排線上端霍爾傳感器排線后超聲波傳感器排線電機(jī)排線通訊排線前超聲波傳感器排線前殼主板電機(jī)面布線示意圖 6. 拆前殼主板(此處可更換維修主板):(1) 將主板從顯示控制板插座上拔出并放好主板。 7. 拆前殼上/下兩個霍爾傳感器(此處可分別更換上/下兩個霍爾傳感器):(1) 先用酒精將固定傳感器的熱熔膠浸濕;(2) 然后用鑷子將熱熔膠去除;(3) 再將霍爾傳感器取出放好,重復(fù)7.17.3將下霍爾傳感器也取出。 下霍爾傳感器位置 8. 拆前殼顯示屏(和顯示屏控制板連在一起)和按鍵面板(此處可更換顯示屏及控制板和按鍵面板):(1) 用螺絲刀將顯示屏控制板的4顆固定螺絲取出,然后將顯示屏及其控制板拿下來。 9. 拆前殼后超聲波傳感器(此處可更換后超聲波傳感器):(1) 用螺絲刀將后超聲波傳感器的2顆固定螺絲取出;(2) 然后將機(jī)器正面的泵門打開,取出后超聲波傳感器。 10. 拆前殼前超聲波傳感器(此處可更換前超聲波傳感器):(1) 用鑷子將壓住前超聲波傳感器線的橡膠墊取出;(2) 然后用螺絲刀將泵門軸的2顆固定螺絲取出,將機(jī)器正面的泵門打開,取下泵門;(3) 再用鑷子將固定前超聲波傳感器的3個螺絲膠墊(右下角螺絲位置無)取出;(4) 再用螺絲刀將固定前超聲波傳感器板的4個螺絲取出,取下固定板;(5) 再用螺絲刀將固定前超聲波傳感器的1個螺絲取出,取下前超聲波傳感器。11. 拆前殼蠕動泵(此處可更換蠕動泵):(1) 用手捏住蠕動泵上端塑膠凸起直接將蠕動泵從前殼取出。 12. 組裝方法請按照以上拆解方法反循序進(jìn)行即可。Part-1- II 機(jī)器設(shè)定Machine Setup1. 電機(jī)工作點調(diào)試Adjustment of motors operating point1.1 目的:解決因工作點不準(zhǔn)馬達(dá)驅(qū)動力不夠引起的“ERR1”ERR6”、 “電機(jī)不動等問題。1.1 Purpose: To solve the problems “ERR1”, “ERR6” or “motor cant start up” caused by deficiency of power due to the inaccurate operating point.1.2 所需工具:(1)數(shù)字萬用表 1個(2)小一字調(diào)試筆 1個1.2 Required Tools(1) Digital multimeter 1pc(2) Screwdriver1pc1.3 機(jī)器設(shè)置:打開機(jī)器前后殼,接上交流電,開機(jī)設(shè)置輸液流速30滴/分鐘(或90毫升/小時),按開始鍵運行機(jī)器;1.3 Relevant settings on pumpSwitch on the pump, and set the infuse rate as 30d/min(or 90ml/h). Push start/stop key to run.Infuse rate: 30d/min or 90ml/h1.4 萬用表接法:在主板上萬用表黑表筆線路接公共接地AGND,紅表筆接電機(jī)工作測試點:V-REF點。1.4 Connection of multimeter(1) Put the negative terminal of multiter on AGND(ground) on motherboard. (2) Put the positive terminal of multiter on V-REF point on motherboard.Motor operating test point:V-REFAGND 1.5 工作點電平規(guī)格區(qū)分:不同的電機(jī)與驅(qū)動芯片搭配要求不同,請參照下表設(shè)置:驅(qū)動芯片工作點電機(jī)7075驅(qū)動芯片7078驅(qū)動芯片SANYO電機(jī)100mv5mv50mv5mv國產(chǎn)電機(jī)200mv5mv105mv5mvSANYO Motor7075 driver chip國產(chǎn)yijin Motor 注意:1、我們的產(chǎn)品除了SANYO電機(jī)外,其它的都是國產(chǎn)電機(jī),故電機(jī)識別時如不是SANYO電機(jī)則為國產(chǎn)電機(jī); 2、同上我們的產(chǎn)品中除了7075驅(qū)動芯片外,就是7078驅(qū)動芯片,故IC識別時如不是7075驅(qū)動芯片則為7078 驅(qū)動芯片。1.5 For different combinations of motor and driver chip, the operating points is shown as below(1) SANYO motor + 7075 driver, operating point should be 100mv5mv(2) SANYO motor + 7078 driver, operating point should be 500mv5mv(3) Non-SANYO motor + 7075 driver, operating point should be 200mv5mv (4) Non-SANYO motor + 7078 driver, operating point should be 105mv5mvYou can distinguish SANYO motor by the label sticked on the motor surface;You can distinguish between motor driver chip 7075 and 7078 by the printing on the chip.1.6 調(diào)試方法:調(diào)節(jié)主板W1電位器,順時針調(diào)小,逆時針調(diào)大,參照1.5表格不同的搭配方式調(diào)到規(guī)定的電機(jī)工作點電壓即可。1.6 Adjustment methodUse the screwdriver to rotate the adjusting point on variable resistor W1, Clockwise direction for decreasing, counterclockwise direction for increasing. Adjust the motors operating point to the value listed above in Step 1.5.下兩圖為 國產(chǎn)電機(jī) + 7075驅(qū)動芯片時電機(jī)工作點調(diào)試實例,請參照作業(yè):The Figures shown below is an example for non-SANYO motor + 7075 driver chip.1. variable resistor W12. Voltage = 200mv 2. 壓力標(biāo)定 Pressure Calibration2.1 目的:解決因壓力出現(xiàn)的“阻塞”、”ERR7”、及壓力報警值不準(zhǔn)問題。2.1 Purpose:To solve the problem described as: “Occlusion” or “ERR7” occur at an inaccurate pressure point.2.2 標(biāo)定方法:2.2 Calibration method2.2.1 調(diào)節(jié)壓力小板初值: 所需工具:(1)數(shù)字萬用表 1個(2)小一字調(diào)試筆 1個 Required Tools(1) Digital multimeter 1pc(2) Screwdriver1pc 操作方法:(1)打開機(jī)器前后殼,打開機(jī)器電源,不用裝輸液管,用萬用表黑線線路接公共地ANGD,紅線接在OCCL測試針上;(2)調(diào)節(jié)壓力小版W1電位器(本體標(biāo)識有“W502”),順時針調(diào)大,逆時針調(diào)小,直到萬用表讀書為8090mv即可。2.2.1 Zero point Calibration. Calibration method: Detach the housing. Power on the machine. Without loading on the pressure sensor, So do not install the IV set on the pump. Connect the Negative terminal of multimeter to AGND and Positive terminal to OCCL. Use the screwdriver to rotate the adjusting point on variable resistor W502(W502 is printed on top of the component), Clockwise direction for decreasing, counterclockwise direction for increasing. Until the reading on multimeter is between 8090mv.AGNDOCCLW502 1. ANGD point2. OCCL point3. W502 variable resistor on the pressure board4. reading= 86mv 2.2.2 0kpa、140kpa壓力的標(biāo)定2.2.2 0Kpa and 140Kpa calibration 所需工具:(1)壓力表(0250 Kpa) 1個(2)輸液瓶 1個(3)輸液器 1條 Required Tools(1) Pressure gauge (0250 Kpa) 1pc(2) Infusion bottle 1pc(3) IV set 1pc1. Pressure gauge2. IV set3. Infusion bottle 機(jī)器設(shè)置: Relevant settings on pump.(1)打開電池蓋,將撥碼開關(guān)4號鍵打至ON位置,設(shè)置輸液速度為:60滴/分鐘;Step1. Detach the battery cover at the bottom of pump. And put the No.4 switch of DIP switch to the ON position. Turn on the pump, and set the infusion rate to 60d/min.(2)將機(jī)器后面阻塞靈敏度檔位設(shè)置為8檔(順時針跳到盡頭);Step2. Set the Pressure sensitivity to level 8 by rotating clockwise the adjustment point located on the back of the machine.Set it “8”Set it “On”Infusion rate = 60d/min 壓力表連接方法:輸液器機(jī)器壓力表帶輸液夾子的導(dǎo)管(可用輸液器管一段代替) Connect the Pressure gauge to the infusion line shown as below. 1. The green arrow indicates the flow direction.2. Roller Clip 0KP壓力標(biāo)定: 0Kpa Calibration:(1)將輸液器接到壓力表和機(jī)器上,壓力表下段夾子打開無阻塞;(2)按開始鍵運行機(jī)器,此時輸液泵的輸液流速窗口和輸液量窗口分別顯示壓力Ad值(設(shè)為X)和壓力變化值,正常情況下輸液泵的輸液流速窗口的壓力Ad值X范圍應(yīng)為: 100X400; (3)機(jī)器運行約一分鐘后,先按停止鍵,接著長按“確認(rèn)/設(shè)置”鍵進(jìn)行0Kpa的壓力標(biāo)定,記下輸液流速窗口的Ad值(即X), 0Kpa的壓力標(biāo)定完畢。 Step1. Install the IV set on machine and connect the pressure gauge to the infusion line,loose the roller clip; Step2. Power on the machine and run it by pushing “Start/stop” key,at this time, the middle of the LCD panel shows the minimum AD value (Named as Xmin), and the lower of the LCD panel shows the immediate Ad value (Named as X). Normally, Xmin should fall into range: 100X400; Step3. After the machine running for about 1 minute, push “start/stop” key to stop the machine. Then Keep pressing down key “Set/confirm” to prompt the machine to mark down the AD value in memory. Whenthe key is released, the stored value will be shown at the middle of LCD panel. 0Kpa calibration finished!1. The stored value is equal to 2492. keep pressing down set/confirm key 140KP壓力標(biāo)定: 140Kpa Calibration:(1)標(biāo)定好0Kpa的壓力后,關(guān)上壓力表出水口夾子,按開始鍵運行機(jī)器,當(dāng)壓力表到達(dá)140Kpa后按停止鍵,再長按“確認(rèn)/設(shè)置” 鍵進(jìn)行140Kpa的壓標(biāo)定,記下輸液流速窗口的Ad值(設(shè)為Y),然后根據(jù)X(0Kpa壓力值)和Y(140Kpa壓力值)計算確認(rèn):如果X/Y符合條件: “X+140Y900” 則說明標(biāo)定壓力成功;(2)標(biāo)定完成后將撥碼開關(guān)4號鍵復(fù)位關(guān)機(jī),再將壓力靈敏度檔位調(diào)為4檔(逆時針旋轉(zhuǎn),在機(jī)器開機(jī)狀態(tài)下機(jī)器發(fā)出4次聲響即可),此時140Kpa的壓力標(biāo)定完畢。 Step1. After calibration of 0KPA, Close the clip to block the infusion line. Then push “Start/stop” key to run the machine. The machine keeps running until the pressure value shown on pressure gauge reaches 140Kpa.Stop the machine by pushing “start/stop”. Then Keep pressing “start/stop” key to mark down the Ad value(named as Y). The stored value would be shown at the middle of the lcd panle. Normally, the Y range should be “X+140Y900” Step2. After calibration, recover the No.4 switch of DIP switch to OFF position and power off the machine. Set the pressure sensitivity to level 4 which will make the machine emit 4 alarm. Calibration finished.1. Stored value for 140Kpa is 6422. Reading on pressure gauge is 140Kpa 3. 電池基準(zhǔn)點電壓標(biāo)定 Battery calibration3.1 目的:解決電池充電不滿、欠壓報警、電池續(xù)航時間短等問題。3.1 Purpose: To solve the problem that the battery can not be fully charged, give a battery low warning by mistake etc. 3.2 所需工具:穩(wěn)壓電源 1臺3.2 Required Tools: Regulated DC voltage supply(shorten as DC supply) 1set3.3 標(biāo)定方法:(1) 打開穩(wěn)壓源,將穩(wěn)壓電源輸出電壓調(diào)到:14.20.05V;(2) 打開電池蓋,將電池取下,把穩(wěn)壓源接到電池接口,將撥碼開關(guān)5號鍵打至“ON”位置;(3) 開機(jī)后長按(約10秒)“向上鍵”進(jìn)行電池基準(zhǔn)點電壓標(biāo)定,輸液流速窗口顯示Ad值范圍在800-900之間,標(biāo)定完成后再將撥碼開關(guān)5號鍵復(fù)位,電池電壓標(biāo)定完畢。3.3 Calibration method: Step1. Turn on the DC supply and adjust its ouput to be 14.20.05V;Step2. Detach the battery cover, replace the battery with DC supply. Then put the No. 5 switch of the DIP switch to ON position. Step3. Turn on the pump. Make the machine enter battery calibration mode by pressing down the key Up for around 10senconds. The bottom of LCD panel shows AD value among 800900. Then you can released the key. Battery calibration is finished.Voltage of DC supply should be 14.20.05V1. Replace battery with DC supply2. Put the No.5 switch to ON. 1. Press down up key.2. Show the Ad value:800900 4. 超聲波傳感器更換后檢測 Testing the Ultrasonic sensor after replacement4.1 目的:避免超聲波傳感器更換后因安裝不好造成無氣泡誤報警或有氣泡不報警的風(fēng)險。4.1 Purpose: To avoid giving an air warning by mistake or no warning when air exists.4.2 所需工具:數(shù)字萬用表 1個4.2 Required Tools: Digital Multimeter 1pc4.3 檢測方法:(1) 連接機(jī)器電源,開機(jī);(2) 萬用表黑筆接線路公共接地點AGND測試針,紅筆接C43內(nèi)側(cè)焊盤作測試點。此時要分兩種情況進(jìn)行確認(rèn):情形1:當(dāng)機(jī)器已裝上輸液器且其管路充滿液體時,萬用表的讀數(shù)應(yīng)為:3.7V0.2V,且顯示屏 “氣泡”字符不閃亮,則說明檢測通過;4.3 Testing Method: Step1. Power on the machine. Step2. Connect the Negative terminal of multimeter to testing point AGND, and the positive terminal to inside pad of C43.Now youll meet two situations and need to check them accordingly as below:1. Negative ternimal is connected to AGND2. Positive terminal is connected to the inside pad of C43.Situation-1: If the infusion line is filled with liquid, the reading on multimeter should be 3.7V0.2V and meanwhile Air on LCD panel is off. 3.7V0.2V will be ok for Situation-1(Value=3.753V)C43 test point(on the left) 情形2:當(dāng)機(jī)器已裝上輸液器但其管路無液體時,萬用表的讀書應(yīng)為:500mV ,且顯示屏 “氣泡”字符閃亮,則說明檢測通過。 Situation-2: If there is no liquid in the infusion line, the reading on multimeter should be less than 500mV. And Air is on on the LCD panel.500mV will be ok for Situation-2(Value=108mV) Part-1- 主板電路圖Mainboard Circuit DiagramPart-1- IV 配件清單Accessories ListPart-2- I 主板程序燒錄及升級1. 所需物件清單1.1 PC機(jī)一臺1.2 HX-801B 或 HX-801C 一臺1.3 電腦USB線/燒錄器/主板排插線一套1.4 燒錄軟件第一次使用需要在電腦上安裝燒錄軟件,我們推薦使用雙龍燒錄軟件SLISP(-可從網(wǎng)站上下載最新應(yīng)用程序,中文安裝界面,使用時可轉(zhuǎn)換成英文界面)(you can get it from: )2. 安裝燒錄軟件因軟件版本不同,安裝步驟可能存在差異,請注意本說明是以V6版為參照Step1. 雙擊電腦上的燒錄安裝程序(已下載),如下:Step2. 程序開始安裝,進(jìn)入到歡迎界面,按“下一步(N)”繼續(xù);. Step3. 選擇“我同意該許可協(xié)議的條款”,按“下一步(N)”繼續(xù);. Step4. 填寫“名稱”和“公司”(可使用默認(rèn)的內(nèi)容不變),按“下一步(N)”繼續(xù);.Step5. 選擇程序安裝路徑(可默認(rèn)不變),按“下一步(N)”繼續(xù);Step6. 選擇程序只對當(dāng)前電腦用戶安裝快捷方式或?qū)λ杏脩艨捎茫赡J(rèn)不改),按“下一步(N)”繼續(xù);Step7. 安裝信息顯示,按“下一步(N)”繼續(xù);Step8. 安裝進(jìn)度顯示無需操作,可按“取消(C)”取消安裝;Step9. 信息提示是否需要查看使用手冊和驅(qū)動安裝指南(可默認(rèn)不改),按“下一步(N)”繼續(xù);Step10. 信息提示程序安裝成功,按“完成(F)”結(jié)束安裝過程;Step11. 程序安裝完成,電腦桌面顯示程序快捷圖標(biāo),表示程序可用。3. 燒錄主板程序Step1. 打開電池蓋,取出電池,接上交流電源;a) 如下圖所示將產(chǎn)品背面朝上放平,用螺絲刀將固定電池蓋板的固定螺絲取出;b) 用手將電池線依次從主板上拔出;c) 取出電池。 Step2. 將燒錄器USB線接入到電腦上(如有硬件驅(qū)動安裝請求可按一般情況自動安裝完成即可),另一端待插到主板上;Step2. CPU 程序燒錄, 將燒錄器主板排線插頭插到 CPU(64位)插座位置(靠近電池插座一側(cè)); CPU-64位(位置-靠電池插座一側(cè))電腦USB連接線燒錄器6-pin主板排線Step3. 雙擊電腦桌面燒錄程序快捷圖標(biāo)打開燒錄程序;Step4. 鼠標(biāo)右擊程序界面最上端,在彈出的菜單欄鼠標(biāo)左擊選擇“English”可將界面轉(zhuǎn)為英文;中文界面 轉(zhuǎn)換語言 英文界面 Step5. 選擇/或確認(rèn)當(dāng)前為“ATMEGA64(L)”芯片,其它設(shè)置默認(rèn)不需改,鼠標(biāo)左鍵點擊“Flash”項選擇所要燒錄的程序文件,彈出確認(rèn)對話框,點擊“OK”確認(rèn),“FLASH Memory” 欄內(nèi)顯示程序路徑; (ReLoad File/Erease Chip/FLASH/Verify ID 4 項默認(rèn)為勾選,請不要去掉) Step6. 鼠標(biāo)左鍵點擊“配置熔絲-Config Fuse”項,彈出“配置熔絲”配置表,選中配置表內(nèi)的對應(yīng)項:(1) 從上到下正數(shù)第一和第三項,(2) 從下到上倒數(shù)第三、五、九和第十三項,點擊“OK”確認(rèn),彈出“確認(rèn)”對話框,點擊“確認(rèn)”即可,最后點擊“編程-Program”開始燒錄程序;選擇從上到下正數(shù)第二和第三項:選擇從下到上倒數(shù)第一、三、五、九和第十三項: 燒錄結(jié)果顯示:Step7. 程序燒錄完成后拔出燒錄線及機(jī)器電源線,重新裝上電池,合上蓋并用螺絲固定,燒錄工作完成。Part-2- 主板程序升級主板程序升級完全可按照程序燒錄方式完成。Part-3-: Trouble Shooting1. 以下是一些常見報警的排除方法,任何有不能自行排除的異常情況,請停止使用并盡快聯(lián)絡(luò)供貨商;報警或故障現(xiàn)象可能故障排除或維修方法“”輸液管安裝不到位檢查輸液管是否裝到氣泡傳感器指定位置;輸液管中有空氣1、打開門,輸液管夾鎖自動鎖緊輸液管;2、將管夾鎖上端的輸液器管路取出;3、輕彈輸液管將氣排到滴液腔中;4、將管路重新安裝,關(guān)門繼續(xù)輸液。進(jìn)氣口阻塞檢查輸液管道進(jìn)氣口是否暢通。未清除前次報警手動按“清除”鍵消除報警。傳感器部件損壞更換超聲波氣泡傳感器“AIR”+“ERROR”氣泡傳感器松脫接插好超聲波氣泡傳感器氣泡傳感器部件損壞更換超聲波氣泡傳感器快排時管道里有氣泡機(jī)器正常,無部件故障主板損壞更換主板“DOOR”泵門開啟關(guān)閉泵門并鎖緊門檢測元件損壞更換門檢測的磁鐵或機(jī)內(nèi)們檢測霍爾元件“”電池電量低內(nèi)置電池電量低如還要長時間輸液請立刻接上市電電池不能充電檢查電源板是否有17V左右輸出,如無更換電源板電池脫落電池線松脫電池?fù)p壞需要更換同型號電池?!癘CCL”進(jìn)氣口阻塞檢查輸液管道進(jìn)氣口是否堵塞、暢通管路安裝不規(guī)范按說明書安裝好管路壓力檢測過于靈敏將壓力檢測檔位設(shè)置為78檔傳感器組件損壞更換壓力傳感器組件“FINISH”自動校準(zhǔn)完成關(guān)機(jī)重啟后再進(jìn)行操作輸液完成。1、換新藥液、設(shè)置參數(shù)繼續(xù)輸液;2、完成輸液,撤除輸液器。電機(jī)轉(zhuǎn)動異常1、受外來干擾。2、電機(jī)組件損壞,更換電機(jī)組件。3、更換主板電機(jī)被卡死轉(zhuǎn)不動檢查卡死原因并排除點滴傳感器脫落或忘插上1、檢查并確認(rèn)傳感器安裝連接正確;2、檢查傳感器接口/連線是否斷裂。點滴傳感器損壞更換點滴傳感器暫停超時(2分鐘)按“”繼續(xù)暫停,按“”繼續(xù)輸液管道漏液1、檢查管路是否有破損、是否安裝好2、檢查門壓板上黑色膠墊是否脫落3、檢查點滴傳感器是否安裝好,是否激烈晃動點滴傳感器損壞更換點滴傳感器檢測不到藥液滴落1、檢查輸液瓶/袋是否空;2、墨菲氏管水霧過多,藥液沒有形成液滴滴落;3、點滴傳感器傾斜,拉直輸液管讓墨菲林管垂直。點滴傳感器損壞更換點滴傳感器泵體不轉(zhuǎn)1、 輸液管不良或安裝不好使泵體卡死;2、 泵體被卡死。檢測零部件損壞1、檢查泵體上磁鐵是否脫落失效;2、機(jī)器內(nèi)部檢測泵體霍爾傳感器是否脫落、損壞。壓力傳感器錯誤1、壓力傳感器線脫落;2、壓力傳感器組件損壞更換壓力傳感器組件。管路阻塞1、管路折疊:檢查輸液管是否被折疊;2、滾動夾關(guān)閉:打開輸液器管夾;3、針頭阻塞:檢查輸液器管路/針頭是否阻塞。管型太硬、太粗由管型造成誤報警,調(diào)節(jié)機(jī)器背后的傳感器壓力閾值傳感器組件損壞更換壓力傳感器組件管型設(shè)置錯誤檢查管型設(shè)置是否與實際管型不符合。輸液異常1、檢查滴速傳感器安裝是否正確?2、墨菲氏管有霧水或液面過高?3、檢測輸液瓶進(jìn)氣口是否有堵塞現(xiàn)象?點滴傳感器損壞更換點滴傳感器報警聲過大適當(dāng)調(diào)小一點音量語音異常請重新開機(jī),如故障不能排除請聯(lián)絡(luò)供應(yīng)商自動校準(zhǔn)完成沒重啟自動校準(zhǔn)完成沒有重新啟動自動校準(zhǔn)的預(yù)置輸液量設(shè)置過低參照用戶手冊增加到要求最低預(yù)置量以上自動校準(zhǔn)失敗自動校準(zhǔn)過程中出現(xiàn)“開門,阻塞,泵體不轉(zhuǎn)”等異常,關(guān)機(jī)后重啟,并重新自動校準(zhǔn)注: 單一故障狀態(tài)下可輸液的最大容量小于0.7毫升。2. 以下是其他故障的排除方法,任何有不能自行排除的異常情況,請停止使用并盡快聯(lián)絡(luò)供貨商;現(xiàn)象檢查點排除故障按“”鍵不能開機(jī)電池是否安裝好?正
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 都勻毛尖茶事件營銷方案
- 建筑方案設(shè)計分析模板
- 咨詢行業(yè)企劃方案范文
- 咨詢規(guī)劃方案模板
- 染料在藝術(shù)品保存中的應(yīng)用效果評估
- 咨詢康復(fù)方案
- 云數(shù)據(jù)中心施工方案
- 咨詢方案多久出
- 厲行節(jié)約-活動方案策劃
- 宜春代理記賬咨詢方案
- 高中英語新課程標(biāo)準(zhǔn)解讀課件
- 部編版《道德與法治》小學(xué)二年級上冊第3課《歡歡喜喜慶國慶》課件
- 七步洗手法操作評分表
- T-CECC 027-2024 生成式人工智能數(shù)據(jù)應(yīng)用合規(guī)指南
- 全國中小學(xué)生學(xué)籍信息管理系統(tǒng)操作手冊學(xué)校級
- 職技術(shù)學(xué)院眼視光技術(shù)專業(yè)學(xué)生技能考核題庫
- 陳閱增普通生物學(xué)全部課件
- 《中國陶瓷史》課件-14漢代青瓷
- 2型糖尿病科普講座課件
- 雙胎妊娠合并早產(chǎn)護(hù)理查房課件
- 2021新高考I卷II卷英語讀后續(xù)寫解讀講評及寫作技巧指導(dǎo)課件
評論
0/150
提交評論